FASTQ Quality Control & Trimming Decisions
Run quality control on raw sequencing reads, interpret the report, and make an evidence-based decision about whether to trim — using real local command-line tools (FastQC, MultiQC, fastp, Cutadapt, seqkit).
Honesty contract (read first)
This skill drives real binaries. It must never fabricate QC numbers.
- Preflight before anything. Check whether the required tools are on PATH. If a required tool is missing, emit the install plan and STOP. Do not estimate, guess, or describe hypothetical QC results.
- Never auto-trim. Trimming is a decision. QC-only is the default.
Only trim after inspecting adapter content / per-base quality, and only
when the user has confirmed
--mode trim. - Never overwrite raw FASTQs. All outputs go to a separate
--workdir. The input directory is read-only. Trimmed reads are written as NEW files. - If you cannot run, say so. "FastQC is not installed; here is the install plan" is the correct answer — not a made-up PASS/FAIL table.
When to use vs. not
Use this skill when the user wants to:
- Run FastQC / fastp QC on one or more FASTQ (
.fastq,.fq,.gz) files - Interpret a FastQC report (per-base quality, adapter content, etc.)
- Decide whether adapter or quality trimming is needed before downstream work
- Summarize many samples into one MultiQC report
- Count reads, get length/GC stats, or subsample with seqkit
- Trim adapters/low-quality bases with fastp or Cutadapt (explicitly)
Do NOT use this skill for (route elsewhere):
- Differential expression / DEG / fold-change analysis ->
tooluniverse-rnaseq-deseq2 - Read alignment, coverage depth, samtools, BWA ->
tooluniverse-sequence-analysis - Variant calling, VCF, VAF, mutation analysis ->
tooluniverse-variant-analysis - Single-cell / scRNA QC (per-cell metrics, scanpy) ->
tooluniverse-single-cell
Essential inputs to confirm
Before running, confirm with the user (ask if unstated):
- FASTQ paths — exact path(s). One file = single-end; an R1+R2 pair =
paired-end (e.g.
*_R1.fastq.gz/*_R2.fastq.gz). - QC-only or trim? Default is QC-only. Only trim on explicit request.
- Known adapters / primers? Standard Illumina adapters are auto-detected by fastp; amplicon/primer sequences usually need explicit Cutadapt removal.
- Organism — only needed if a contamination / over-representation screen is requested (needs a reference; see Limitations).
- Output directory — a
--workdirSEPARATE from the input folder. - Read provenance — are these raw, already-trimmed, or UMI-tagged reads? Already-trimmed reads should NOT be trimmed again; UMIs must be handled before trimming or you corrupt the UMI.
Preflight (do this first, every time)
The bundled script preflights for you, but the decision logic is:
import shutil
for tool in ("fastqc", "fastp", "seqkit"):
print(tool, shutil.which(tool) or "MISSING")
command -v fastqc / shutil.which("fastqc") returning nothing means the
tool is absent. If a required tool (FastQC for QC; FastQC+fastp for trim)
is missing, emit:
mamba install -c bioconda -c conda-forge fastqc fastp seqkit multiqc
# or
conda install -c bioconda -c conda-forge fastqc fastp seqkit multiqc
and stop. Do not proceed to fabricate output.
Tool roles
| Tool | Role | Install (bioconda) |
|---|---|---|
| FastQC | Per-file raw read QC; produces the module PASS/WARN/FAIL report | fastqc |
| MultiQC | Aggregates many FastQC (and fastp) reports into one summary | multiqc |
| fastp | All-in-one QC + adapter + quality trimming (fast, auto-detect) | fastp |
| Cutadapt | Explicit, precise adapter/primer removal (amplicons, custom) | cutadapt |
| seqkit | Read counts, length/GC stats, subsampling | seqkit |
Rule of thumb: FastQC to diagnose, fastp to fix general adapter/quality, Cutadapt to fix a known primer/adapter precisely, seqkit to count/stat.
Bundled orchestration script
scripts/run_fastq_qc.py does the preflight + run-if-available + plan-if-missing
flow, with workspace isolation built in.
# QC only (default) — never modifies reads
python scripts/run_fastq_qc.py \
--fastq reads/sample_R1.fastq.gz reads/sample_R2.fastq.gz \
--workdir /tmp/fastq_qc_run
# QC + trim (explicit) — fastp writes NEW trimmed files into --workdir
python scripts/run_fastq_qc.py \
--fastq reads/sample_R1.fastq.gz reads/sample_R2.fastq.gz \
--workdir /tmp/fastq_qc_run \
--mode trim
Behavior:
- Preflights FastQC (+ fastp in trim mode) and seqkit. If a required tool is missing it prints the install plan and exits 0 — no fabricated QC.
- Runs FastQC (always) + seqkit stats (if present) into
--workdir. - In
--mode trim, runs fastp writing*.trimmed.fastq.gzinto--workdir/trimmed/— raw inputs are never touched. - Refuses to run if
--workdirequals an input directory (overwrite guard).
For a project-level summary after FastQC, run MultiQC over the workdir:
multiqc /tmp/fastq_qc_run -o /tmp/fastq_qc_run/multiqc
INTERPRETATION — FastQC module -> meaning -> action
This table is the core value-add. Map each FastQC module to what PASS/WARN/FAIL
means and what to actually do. (See references/fastqc_interpretation.md for the
long form with thresholds and worked cases.)
| FastQC module | Typical PASS | WARN / FAIL means | Suggested action |
|---|---|---|---|
| Per base sequence quality | All positions Q>=28 | 3' tail drops below Q20-Q28 (common, esp. R2) | Quality-trim 3' (fastp -q/sliding window). Proceed if only the last few bases dip. |
| Per base N content | Near 0% N | Spike of N at a position = sequencer/base-call problem | Investigate: cycle-specific issue; consider hard-trim that position or re-sequence. |
| Adapter content | Flat, no adapter ramp | Rising adapter % toward 3' end = read-through into adapter | Trim adapters (fastp auto-detect, or Cutadapt with the known adapter). |
| Overrepresented sequences | None / <0.1% | A sequence is a large fraction: adapter, primer-dimer, rRNA, or low-complexity | Investigate the hit (BLAST it). If adapter/primer -> trim. If biology (rRNA/highly-expressed) -> proceed. |
| Sequence Duplication Levels | Low (diverse library) | High duplication = PCR over-amplification OR expected (amplicon/RNA-seq) | Investigate, usually proceed. Do NOT dedup blindly — expected high in amplicon/targeted/RNA-seq. Mark-duplicates belongs post-alignment, not here. |
| Per sequence GC content | Single peak at expected GC | Bimodal / shifted peak = contamination or mixed species | Investigate contamination (needs a reference screen; see Limitations). Not fixed by trimming. |
| Per base sequence content | Flat after first ~10 bp | Bias in first bases (random-hexamer priming) or adapter | Random-priming bias: usually proceed (expected in RNA-seq). Persistent bias at 3' -> adapter -> trim. |
| Sequence Length Distribution | Single length (raw) | Multiple lengths AFTER trimming is normal; before trimming may indicate mixed input | Usually proceed; only a concern on supposedly-raw uniform-length data. |
Decision summary for "do I need to trim?"
- Adapter content FAIL/WARN with a 3' adapter ramp -> yes, adapter-trim.
- Per-base quality FAIL at the 3' tail -> yes, quality-trim that tail.
- Overrepresented = adapter/primer-dimer -> yes, trim; overrepresented = biology (rRNA, abundant transcript) -> no, proceed.
- High duplication / GC anomaly / N-spike -> investigate, not a trimming fix.
- Everything PASS -> proceed without trimming.
Workflow
- Confirm inputs (paths, pairing, mode, adapters, provenance).
- Preflight tools. If missing -> install plan, STOP.
- Run QC (
--mode qc): FastQC + seqkit -> read the report. - Interpret each flagged module with the table above.
- Decide trim vs investigate vs proceed. State the decision and why.
- (If trimming chosen) run
--mode trim(fastp) or Cutadapt for precise primer removal; re-run FastQC on the trimmed output to confirm the fix. - (Optional) MultiQC for a multi-sample summary.
- Report: per-module status, the trim decision + rationale, and the exact commands run. Never report numbers a tool did not actually produce.
Limitations (honest)
- Requires local binaries. FastQC/fastp/seqkit/Cutadapt/MultiQC must be installed (bioconda). This is not a cloud service; with no tools installed the skill can only emit an install plan, not QC results.
- Large files. Whole-lane FASTQs can be many GB; FastQC/fastp are
single-pass and memory-light but still I/O-bound. Use seqkit
sampleto subsample for a quick look on huge files. - Contamination / cross-species screening is NOT included by default. GC anomalies and "is this the right organism" need a reference index (e.g. FastQ Screen + bowtie2 indexes, or Kraken2) — extra setup beyond this skill's bundled tools.
- No deduplication of raw reads. PCR-duplicate removal is an alignment-stage decision (Picard/samtools markdup); FastQC duplication is diagnostic only.
- UMI-aware trimming needs UMI extraction first (umi_tools); naive trimming corrupts UMIs.
Completeness checklist
- Inputs confirmed (paths, single/paired, raw vs trimmed, adapters)
- Tools preflighted; install plan emitted if any required tool missing
- QC run with outputs in a workdir separate from inputs (raw preserved)
- Each flagged FastQC module interpreted (meaning + action)
- Explicit trim/investigate/proceed decision with rationale
- Trimming (if done) was opt-in, wrote new files, raw FASTQs untouched
- Post-trim FastQC re-run to confirm the fix (if trimmed)
- No QC numbers reported that a tool did not actually produce
References
references/fastqc_interpretation.md— full module-by-module thresholds + casesreferences/tools_and_install.md— install commands, tool flags, command recipesreferences/trimming_decisions.md— when/how to trim (fastp vs Cutadapt), pitfalls