Membrane autopsy lab methodology — autopsy decision matrix (when to autopsy), element sampling protocol (which to pick, preservation, data package), lab method suite (visual / weight-loss / dye test per ASTM D6908 / SEM-EDS / FTIR / swab + plate count / Fujiwara chlorine test / cross-section), findings-to-action interpretation table, independent and vendor-affiliated labs with cost ranges, warranty claim workflow (open BEFORE pulling the element), bilingual glossary. Use when planning or interpreting an autopsy, or filing a manufacturing-defect warranty claim.

GitHub
Install command
npx skhub add claude-dev-suite/membrane-autopsy
Markdown
SKILL.md

Membrane Autopsy

Reference for deciding when to autopsy a membrane element, how to ship it, what each lab method reveals, and how to translate findings into operational action or a warranty claim.

Convention markers:

  • ⚠️ — likely bug or incorrect assumption in calling code
  • 💡 — enhancement opportunity (autopsy-driven lifecycle update, vendor warranty workflow integration)

§1 — When to Autopsy (Decision Matrix)

1.1 Trigger conditions (any one suffices)

TriggerThresholdNotes
Salt rejection drop (passage rise)> 10 % vs baseline, persistent after 2 CIPsAvista / AWC / Vipanan canonical trigger
Normalized ΔP (ΔPn) rise> 15–25 % not recovered by CIPDuPont 45-D01652: 15 % action; many operators use 20–25 % post-CIP
Normalized permeate flow (NPF) decline> 10–25 % not recovered by CIPBiofouling signature: ΔP impacted first, then flux, then rejection
Unexplained instrument disagreementPersistent after sensor calibrationRules out membrane vs instrumentation root cause
End-of-warranty diagnosticBefore warranty expiryRequired to file manufacturing-defect claim
Premature failure patternMultiple elements < expected lifeEspecially when concentrated in lead or tail positions
Suspect chlorine breakthroughCumulative ppm·h record exists OR ORP excursionFujiwara test confirms halogenation
Pre-replacement diagnosticBefore bulk replacement decisionValidates cleaning options before procurement

1.2 Cost-benefit framing

Public vendor websites do not publish autopsy price lists — all require a quote. Indicative ranges from industry practice (planning indicators, not contractual):

ScopeIndicative range (USD)Use case
Basic: visual + dye + weight-loss~$500–1 000Quick screen, single element
Standard (Genesys "Tier 2-3"): + SEM/EDS + FTIR + cleaning study~$1 500–2 500Most common; supports warranty claim
Advanced (Tier 4-5): + 16S rRNA + cross-section + Fujiwara + ATP + LOI~$2 500–5 000Complex/persistent failures, expert-witness
Vendor warranty autopsy (DuPont, Hydranautics, Toray)Free, if claim acceptedRMA process; vendor-affiliated lab

Pays off when: multiple elements need replacement, warranty claim plausible, recurring failure pattern needs root-causing.


§2 — Sampling Protocol

2.1 Which element to autopsy

PositionWhat it revealsWhen to pick
Lead element of lead vesselParticulate / colloidal fouling, biofouling, oxidation damage, organics, oil/greaseDefault; fouling-dominant problems; suspected chlorine breakthrough
Tail element of last vesselScaling (CaCO₃, CaSO₄, BaSO₄, SiO₂), compactionRejection drop suspected scale-driven; LSI/recovery review
Lead + tailComplete fouling pictureGenerous budget, systemic problem
Failed element (via probing)Localized integrity lossProbing identifies a specific outlier

For budget-limited cases pick lead unless symptoms point to tail.

2.2 Element preparation post-removal

  1. Do not air-dry — desiccation alters biofilm morphology and chemistry, masks NOM, kills microbial signal
  2. Wrap in heavy plastic (double-bag); label with element serial, position, removal date
  3. Refrigerate at 4 °C within 24 h; ship in insulated container with cold packs
  4. Do not freeze — ice crystals damage PA and disrupt cross-section integrity
  5. Ship within 48–72 h
  6. Photograph all external surfaces under good light before shipment (telescoping, glue line, end-cap, brine seal, fiberglass shell). Photos are essential for warranty claims

⚠️ Do not preserve the entire element in SMBS if microbial culture from the main sample is required — SMBS suppresses what you want to grow. Keep a separate witness coupon in 0.5–1 % SMBS if biofilm is the suspect and shipping is slow.

2.3 Pre-autopsy data package (ship with the element)

The lab — and, if applicable, the vendor warranty desk — both require:

  • Element identifier (serial number, model, lot, manufacture date)
  • Position in train (rack / vessel / position), hours on-stream
  • Feed water source + quality history (TDS, SDI, T, pH, alkalinity, hardness, silica, Fe/Mn, oils, chlorine, ORP)
  • Baseline NPF / NSP / ΔPn and recent normalized values
  • CIP history (dates, chemistry, pH, T, contact time, recovery achieved)
  • Cumulative free chlorine exposure if tracked (ppm·h)
  • Abnormal event log (pressure shocks, dosing failures, dechlor failures, feed upsets)
  • ORP / free-Cl₂ continuous log around the suspected exposure event
  • Photographs taken at removal

⚠️ Without this data package the lab can identify the what but not the why, and warranty submissions are routinely rejected for missing pretreatment logs.


§3 — Lab Method Suite

For each: what it reveals, indicative cost, limitations.

3.1 Visual inspection

  • External: telescoping, fiberglass cracks, glue-line cracks, abrasion, brine-seal damage, biofilm rim on lead face, surface color (brown = Fe, white/tan = scale, dark green-brown = biofilm/NOM)
  • Internal (after dissection): leaf-by-leaf deposit distribution, spacer compaction, permeate-spacer imprint on PA (compaction signature)
  • Cost: included in any autopsy package
  • Limitation: qualitative

3.2 Weight-loss / Loss-on-Ignition (LOI)

  • Reveals: total foulant mass and organic vs inorganic split. Wet weight baseline → post-CIP weight (mass removed); coupon ashed at 550 °C (organic burns off, inorganic residue remains)
  • Cost: ~$100–200 add-on
  • Limitation: bulk number; doesn't identify foulant species

3.3 Cleaning effectiveness test

  • Reveals: whether field CIP can recover the element. Bench cell applies sequential chemistries (high-pH detergent → low-pH acid → non-oxidizing biocide → reductant if needed) and re-measures flux + rejection after each step
  • Decision rule:
    • Recovery ≥ 90 % → CIP-treatable in field, deploy the recipe
    • 70–90 % → marginal; consider one more aggressive CIP, then replace
    • < 70 % → replace; no CIP benefit
  • Cost: ~$300–600
  • Limitation: bench cell ≠ field hydraulics; treat as upper bound

3.4 Salt-rejection retest

  • Reveals: membrane chemistry change. Standard conditions per vendor (typically 2 000 ppm NaCl, 225 psi, 15 % recovery, 25 °C for BWRO; 32 000 ppm NaCl, 800 psi for SWRO)
  • Interpretation: rejection > 5 % below vendor spec → confirmed chemical/structural damage (oxidation, hydrolysis, compaction) → replacement
  • Cost: ~$200–400
  • Limitation: does not identify cause, only confirms loss

3.5 Dye test (Rhodamine WT or Red Dye #40 per ASTM D6908)

  • Reveals: integrity defect location and type. ASTM D6908 lists Rhodamine WT and Red Dye #40 (both MW ~500) as soluble-dye tracers for RO/NF
Stain patternDefect
Diffuse, full-membraneChemical attack (oxidation, hydrolysis) — confirm with Fujiwara
Localized pointPinhole — hydraulic shock, particulate puncture
Linear / straight lineGlue-line crack — manufacturing or handling
Edge concentrationO-ring or brine-seal bypass
  • Methylene blue is the cheaper alternative
  • Cost: ~$150–300 — cheapest discriminating test
  • Limitation: confirms breach but not chemistry of attack

3.6 SEM / EDS

  • SEM: high-resolution surface morphology — foulant thickness, crystal habit (rhombohedral CaCO₃, needle CaSO₄, tabular BaSO₄), biofilm 3D structure
  • EDS: elemental composition, semi-quantitative. Map: Ca, Mg, Ba, Sr, Si, Fe, Mn, Al, S, P, C, N, Na, Cl

Cheat sheet:

EDS dominant elementsFoulant
Ca + C (+ Mg)CaCO₃ scaling
Ca + SCaSO₄
Ba + SBaSO₄ (very low solubility — usually irreversible)
Sr + SSrSO₄
Si dominantSilica (amorphous or quartz)
Fe (± Mn)Iron/manganese oxide
Al + SiAluminosilicate (clay)
C + N + P high, low metalsBiofilm / organic
P + CaCalcium phosphate
  • Cost: ~$300–500 per coupon
  • Limitation: surface-sensitive (top ~1 µm), semi-quantitative, heterogeneity-prone (sample ≥ 3 spots). EDS cannot detect H; light elements (B, Li) unreliable

3.7 FTIR / ATR-FTIR

  • Reveals: organic functional groups in deposits and integrity of polyamide active layer
Band (cm⁻¹)Assignment
1650 (amide I, C=O)Protein OR polyamide active layer
1540–1550 (amide II, N–H)Protein / polyamide
1010–1040Polysaccharides (biofilm EPS)
1720 (C=O carboxylic)Humic / NOM
1080 (Si–O–Si)Silica
1450, 870 (CO₃²⁻)Carbonate
2800–3000 (C–H)Aliphatic — oil/grease, surfactant, antiscalant residue

Loss/shift of amide I/II from the polyamide itself indicates oxidative degradation.

  • Cost: ~$200–400
  • Limitation: detects organics in top few µm; overlapping bands need expert interpretation

3.8 Biofilm characterization

  • R2A agar swab / plate count — low-nutrient medium for slow-growing oligotrophs; reports CFU/cm²
  • ATP assay — total live biomass; fast (~minutes); good for trending
  • 16S rRNA sequencing — full community profile. Recurring problem genera on RO membranes: Sphingomonas (dominant biofilm initiator), Pseudomonas, Mycobacterium, Acinetobacter, Burkholderia, Halomonas
  • Cost: $200 (plate count) → $800+ (sequencing)
  • Limitation: R2A captures only culturable fraction (often < 1 % of community); sequencing requires intact DNA — don't ship dry or autoclaved samples

3.9 Fujiwara test (chlorine attack confirmation)

  • Reveals: presence of halogenated organics in/on polyamide → confirms chlorine (or chloramine, bromine) attack
  • Procedure: membrane coupon in tube with 2 mL pyridine + 3 mL 10 % NaOH, heated to boiling ~1 min. Pink/red colour in the caustic layer = positive (halogenated organic present)
  • Cross-verify with FTIR (amide-band shifts) and EDS (Cl detection)
  • Cost: ~$100–200
  • Limitation: qualitative; does not quantify exposure dose; false negatives possible if exposure was brief and PA heavily rinsed. Bromine and iodine also produce positive results

3.10 Cross-section analysis

  • Reveals: active layer (PA), polysulfone support, polyester backing condition; compaction extent; delamination; foulant penetration depth
  • Method: embed in epoxy → microtome → optical or SEM imaging
  • Cost: ~$400–800
  • Use: advanced failure analysis, manufacturing-defect substantiation (PA voids, support delamination)

3.11 Optional: PDT / VDT (per ASTM D6908)

Pressure or vacuum decay test — pressure applied to permeate side, decay rate quantifies leak. More common at module/system level than on a dissected element, but useful when the lab runs an integrity workflow.


§4 — Findings → Root Cause → Action

Lab findingRoot causeOperational action
EDS Ca + C dominant, rhombohedral SEM crystalsCaCO₃ scalingReview LSI/S&DSI at concentrate; antiscalant dose/selection; acid CIP (citric or HCl, pH 2–3)
EDS Ca + SCaSO₄ scalingLower recovery OR upgrade antiscalant (HEDP, polyacrylate); chelant CIP (EDTA pH 11–12)
EDS Ba + S (or Sr + S)BaSO₄ / SrSO₄ scaling — generally irreversibleAntiscalant upgrade to DTPMP; if extensive, replace
EDS Si dominantSilica scalingReview pH, T, recovery; warm-water alkaline CIP (pH 11–12, ≥ 35 °C if vendor allows); if cemented, replace
EDS Fe (± Mn), reddish SEMIron / manganese oxidation upstreamAudit prefiltration / oxidation / pH; reductive CIP with sodium hydrosulfite (Na₂S₂O₄) at 1 %, pH 5; or citric + ammoniated citric
EDS high C, N, P; SEM biofilm; ATP highBiofoulingNon-oxidizing biocide CIP (DBNPA, isothiazolinone); reduce AOC upstream; consider continuous low-dose
FTIR humic peaks (~1720, 1620 cm⁻¹)Organic NOM foulingUpstream coagulation review; alkaline CIP (NaOH + EDTA pH 12)
FTIR C-H aliphatic, EDS C onlyOil / grease / surfactantPretreatment audit; intake protection; surfactant CIP
Dye diffuse + Fujiwara positiveChlorine / chloramine oxidationDechlor failure — audit SBS dosing / ORP loop; replace element
Dye localized pointMechanical pinholeInvestigate pressure shocks, particulate breakthrough; replace
Dye linear lineGlue-line crackManufacturing defect → warranty claim; replace
Dye edge concentrationO-ring / brine-seal failureReplace seal, verify orientation, re-test
Salt-rejection retest > 5 % below spec, FTIR amide changeChemical attack or hydrolysisReplace
Permeate-spacer imprint on PA, low NPFCompactionReduce feed pressure; replace if severe
Cleaning recovery ≥ 90 %CIP-treatableDeploy proven recipe in field; schedule CIP frequency
Cleaning recovery < 70 %ReplaceNo CIP benefit

§5 — Vendor Labs and Cost Ranges

Independent / third-party labs (paid)

  • Avista Technologies (Kurita) — proprietary Chromatic Elemental Imaging (CEI℠) + standard suite; specialty in TFC polyamide
  • American Water Chemicals (AWC) — > 20 tests per autopsy; antiscalant compatibility studies
  • Genesys / PWT (Madrid, ES + Vista, CA, US) — five tiers from screening to expert-witness
  • Ecolab / Nalco Water — full-service water treatment provider
  • Vipanan Lab (IN) — full autopsy suite
  • Membrane Works (AU), ChemEnergy (US), MPW (US) — regional providers

Vendor-affiliated (free with valid warranty claim)

  • DuPont (FilmTec), Hydranautics (Nitto), Toray, LG Chem, Suez/Veolia — autopsy under RMA process
  • ⚠️ Open the claim BEFORE removing the element

Academic / research

  • University of Twente (NL), Singapore CleanTech, university desalination centers — research-grade autopsies under collaborative arrangements (often months turnaround)

§6 — Warranty Claim Workflow

6.1 Typical warranty terms (verify on the actual element warranty document)

Manufacturer terms vary and are shorter than industry folklore suggests:

  • DuPont FilmTec: 3-year prorated limited warranty
  • Toray: 3-year prorated limited warranty on RO elements
  • Hydranautics: standard workmanship-and-materials text is 12 months. Pre-sales agreement may extend; always check the specific PO/contract.

⚠️ The "3 yr SWRO / 5 yr BWRO" working assumption commonly seen in process literature is not universally accurate. Hydranautics' standard text is 12 months. Treat per-vendor PO terms as authoritative.

6.2 Common exclusions (consistent across vendors)

  • Free chlorine or other oxidizing exposure (Hydranautics excludes any free-Cl; many vendors specify > 0.1 ppm)
  • Operation outside pH range (e.g. 2–11 continuous; cleaning extremes per vendor)
  • Feed water SDI > 3–5 (Hydranautics: > 3)
  • Feed temperature > 45 °C
  • Operation outside vendor-specified pressure, recovery, flux
  • Mechanical mishandling, telescoping, hydraulic shock
  • Use of non-approved cleaning chemicals
  • Unauthorized modification

6.3 Documentation the vendor will request

  • Element traceability — serial numbers, PO, install date
  • Plant operating logs (T, P, feed/permeate flow, conductivity)
  • Normalized performance data (NPF, NSP, ΔPn over time)
  • CIP records (dates, chemistries, pH, T, contact time, recovery)
  • Feed water analyses (full panel with sufficient history)
  • SDI continuous or daily log
  • Free chlorine and ORP continuous log (proves dechlor compliance)
  • Pretreatment configuration and any upstream incident reports
  • Photographs taken at removal

6.4 Process

  1. Open the claim BEFORE pulling the element. Some vendors require witness or specify the disassembly procedure. Pulling first can void the claim.
  2. Vendor issues RMA / return authorization
  3. Ship per vendor instructions (refer to §2.2). Vendor autopsy is performed at no cost if the claim is accepted
  4. Outcomes:
    • Manufacturing defect confirmed (glue void, PA pinhole, support delamination): warranty replacement (prorated if applicable)
    • Operational cause confirmed (chlorine breakthrough, pH excursion, SDI > limit, telescoping): claim denied; element returned or scrapped
    • Inconclusive: vendors may offer goodwill credit case-by-case
  5. Independent autopsy first is a defensible strategy when:
    • claim is high-value (multiple elements affected)
    • or trust in vendor diagnosis is low — bring independent SEM/EDS/FTIR/Fujiwara evidence to negotiation

💡 A warranty_workflow.md operational SOP that codifies "open RMA before pulling element" + "ship with data package per §2.3" should live in the plant operator handbook, not just in the asset management system.


§7 — Bilingual IT/EN Glossary

ENIT
Membrane autopsyAutopsia (della) membrana
Foulant identificationIdentificazione del foulant / dello sporcante
Dye testTest di colorazione
Weight-loss testTest di perdita di peso
Loss-on-ignition (LOI)Perdita per calcinazione
Cross-sectionSezione trasversale
SEM (Scanning Electron Microscopy)Microscopia elettronica a scansione
EDS (Energy-Dispersive Spectroscopy)Spettroscopia a dispersione di energia
FTIRSpettroscopia FTIR
ATR-FTIRFTIR in riflettanza totale attenuata
Swab plate countConta in piastra da tampone (swab)
Fujiwara testTest di Fujiwara
Warranty claimReclamo in garanzia
Premature failureGuasto prematuro
Manufacturing defectDifetto di fabbricazione
TelescopingTelescopaggio (deformazione assiale)
Glue lineLinea di colla / incollaggio
Brine sealGuarnizione di concentrato
O-ringGuarnizione O-ring
Lead elementElemento di testa
Tail elementElemento di coda
Normalized permeate flowPortata permeato normalizzata
Normalized salt passagePassaggio sale normalizzato
CompactionCompattazione
BiofoulingBiofouling / sporcamento biologico
ScalingIncrostazione
CIP (clean-in-place)Lavaggio in posto
Reductive cleaningLavaggio riducente
Free chlorineCloro libero
ORPPotenziale di ossido-riduzione
SDI (Silt Density Index)Indice di intasamento (SDI)
Independent autopsyAutopsia indipendente / di terza parte
Vendor-affiliated autopsyAutopsia presso lab del costruttore
RMA (Return Material Authorization)Autorizzazione al reso
Witness section / couponCampione di riscontro

Sources

  • ASTM D6908 — Integrity Testing of Water Filtration Membrane Systems (Rhodamine WT, Red Dye #40 tracers; PDT, VDT)
  • DuPont FilmTec 45-D01650 (Symptoms of Trouble), 45-D01652 (High Pressure Drop), 45-D01504 (Tech Manual), 45-D01569 (Chlorination/Dechlorination), 45-D01575 (Iron/Mn Prevention)
  • Hydranautics TSB 107 (Foulants & Cleaning), TSB 207 (Cleaning Procedures); Standard Workmanship and Materials Warranty
  • Toray RO Element Three-Year Prorated Limited Warranty
  • Avista / Kurita — Avista Membrane Autopsy with CEI; Foulant Identification leaflet
  • American Water Chemicals — How to Identify Damaged RO Membranes
  • Genesys / PWT — Membrane Autopsy services (five tiers)
  • Ecolab / Nalco Water — Water Filtration and RO Membrane Autopsies
  • Vipanan Lab (2025) — Hidden Causes of RO Membrane Failure
  • Reverse Osmosis Membranes Oxidation by Hypochlorite and Chlorine Dioxide: Spectroscopic Techniques vs Fujiwara Test — DeSWater
  • Membrane Works (AU) — Identifying oxidative damage using the Fujiwara test
  • Characterization of New and Fouled SWRO Membranes by ATR/FTIR Spectroscopy — Applied Water Science (Springer)
  • Biofilm Formation on Reverse Osmosis Membranes Is Initiated and Dominated by Sphingomonas spp — Applied and Environmental Microbiology
  • Isolation and characterization of Sphingomonadaceae from fouled membranes — npj Biofilms & Microbiomes
  • Molecular weight insight into critical component contributing to RO membrane fouling — npj Clean Water
  • Autopsy of Used RO Membranes from the Largest Seawater Desalination Plant in Oman — Membranes 2022 (PMC9322904)
  • Hardy Diagnostics — R2A Agar technical sheet
  • Why there is no warranty for RO membranes — Netsol Water (industry exclusions summary)